Figure 7. Rear Air Tank.
Figure 9. Front Air Tank.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  547    548    549    550    551  552  553    554    555    556    557  
img
.
TM 5-3805-296-23-5
0333
ASSEMBLY
000333
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area. If ingested, keep individual calm and
seek medical attention. DO NOT induce vomiting. If contact with skin or eyes is made,
flush thoroughly with water. Dispose of cleanup rags IAW local policy and ordinances.
Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses and fittings as tagged and marked during removal.
1. Apply sealant to fitting (Figure 8, Item 9), install fitting on air tank (Figure 8, Item 2).
2. Apply sealant to fitting (Figure 8, Item 10) install fitting on (Figure 8, Item 9).
3. Apply sealant to fitting (Figure 8, Item 8) install fitting on air tank (Figure 8, Item 2).
4. Apply sealant to fitting (Figure 8, Item 7) install fitting on fitting (Figure 8, Item 8).
5. Apply sealant to fitting (Figure 8, Item 6) install fitting on air tank (Figure 8, Item 2).
6. Apply sealant to check valve (Figure 8, Item 5) install check valve on fitting (Figure 8, Item 6).
7. Apply sealant to fitting (Figure 8, Item 4) install fitting on check valve (Figure 8, Item 5).
8. Apply sealant to pipe plug (Figure 8, Item 3) install pipe plug on air tank (Figure 8, Item 2).
9. Apply sealant to fitting (Figure 8, Item 11) install fitting on fitting (Figure 8, Item 1).
10. Apply sealant to fitting (Figure 8, Item 1) install fitting on air tank (Figure 8, Item 2).
Figure 8. Rear Air Tank.
0333
0333-9