TM 5-3805-296-23-5
0319
REMOVAL CONTINUED
21. Remove fitting (Figure 12, Item 8) and O-ring (Figure 12, Item 7) from fitting (Figure 12, Item 9). Discard O-ring.
22. Remove fitting (Figure 12, Item 9) from hydraulic tank outlet tube (Figure 12, Item 1).
23. Remove O-ring (Figure 12, Item 10) from fitting (Figure 12, Item 9). Discard O-ring.
24. Remove hydraulic fluid temperature sensor (Figure 12, Item 6) and O-ring (Figure 12, Item 4) from hydraulic
tank outlet tube (Figure 12, Item 1). Discard O-ring.
NOTE
Note orientation of clamps to aid in installation.
25. Loosen two clamps (Figure 12, Item 5) and remove hose (Figure 12, Item 3) from hydraulic tank outlet tube
(Figure 12, Item 1).
NOTE
Note orientation of clamp to aid in installation.
26. Remove clamp (Figure 12, Item 2) from hydraulic tank outlet tube (Figure 12, Item 1).
Figure 12. Hydraulic Oil Temperature Sensor.
0319
END OF TASK
CLEANING AND INSPECTION
000319
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK