Figure 27. Right Starter Cable at Junction Block.
STARTER NEGATIVE CABLE REPLACEMENT

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  271    272    273    274    275  276  277    278    279    280    281  
img
.
TM 5-3805-296-23-5
0310
RIGHT STARTER POSITIVE CABLE INSTALLATION CONTINUED
NOTE
Route cable as noted during removal.
12. Install right starter cable (Figure 28, Item 5), P-clamp (Figure 28, Item 3), washer (Figure 28, Item 2), and bolt
(Figure 28, Item 1) on boss (Figure 28, Item 4).
Figure 28. Right Starter Cable P-clamp at Frame by Junction Block.
0310
13. Install muffler (WP 0205).
END OF TASK
FOLLOW-ON TASKS
000310
1. Close right engine doors (TM 5-3805-296-10).
2. Close front hood (TM 5-3805-296-10).
3. Verify correct operation of machine (TM 5-3805-296-10).
END OF TASK
END OF WORK PACKAGE