Figure 21. Left Starter Cable Inner Frame Mounting.
Figure 23. Right Starter Cable P-clamps.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  265    266    267    268    269  270  271    272    273    274    275  
img
.
TM 5-3805-296-23-5
0310
LEFT STARTER POSITIVE CABLE INSTALLATION CONTINUED
NOTE
Route cable as noted during removal.
Install electrical connections as noted during removal.
16. Install left starter cable (Figure 22, Item 6) on junction block terminal (Figure 22, Item 1).
17. Install battery cable (Figure 22, Item 5) on junction block terminal (Figure 22, Item 1).
18. Install washer (Figure 22, Item 3) and nut (Figure 22, Item 2) on junction block terminal (Figure 22, Item 1).
19. Position cover (Figure 22, Item 4) on junction block terminal (Figure 22, Item 1).
Figure 22. Left Starter Cable at Junction Block.
0310
20. Raise crankcase guard (WP 0374).
END OF TASK
0310-23