Figure 17. Negative Battery Cable P-clamp at Right Frame Rail.
BATTERY CABLE REPLACEMENT - Continued

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  210    211    212    213    214  215  216    217    218    219    220  
img
.
TM 5-3805-296-23-5
0307
NEGATIVE BATTERY CABLE INSTALLATION CONTINUED
000307
NOTE
Route and install cables as noted during removal.
9. Install negative battery cable (Figure 18, Item 6) on battery disconnect switch (Figure 18, Item 5).
NOTE
If equipped with Arctic Start Aid, perform step 8. If not equipped with Arctic Start Aid,
proceed to step 9.
Route and install cables as noted during removal.
10. Install negative Arctic Start Aid battery cable (Figure 18, Item 2) on battery disconnect switch
(Figure 18, Item 5).
11. Install new lockwasher (Figure 18, Item 3) and nut (Figure 18, Item 4) on battery disconnect switch
(Figure 18, Item 5).
12. Position cover (Figure 18, Item 1) on nut (Figure 18, Item 4).
Figure 18. Negative Battery Cable at Battery Disconnect Switch.
0307
END OF TASK