• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 15. Battery Crossover Cable.
Figure 17. Negative Battery Cable P-clamp at Right Frame Rail.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  208    209    210    211    212  213  214    215    216    217    218  
img
.
TM 5-3805-296-23-5
0307
NEGATIVE BATTERY CABLE INSTALLATION
000307
NOTE
Route and install cables as noted during removal.
1. Install negative battery cable (Figure 16, Item 5) on machine.
2. Install two negative battery cable grommets (Figure 16, Items 1 and 10) on frame rail (Figure 16, Item 6).
3. Position flanges (Figure 16, Items 2 and 9) on grommets (Figure 16, Items 1 and 10).
4. Install two washers (Figure 16, Item 3) and bolts (Figure 16, Item 4) on machine.
5. Install two bolts (Figure 16, Item 7), and washers (Figure 16, Item 8) on machine.
6. Install P-clamp (Figure 16, Item 11), hose (Figure 16, Item 14), washer (Figure 16, Item 13), and bolt
(Figure 16, Item 12) on frame rail (Figure 16, Item 6).
Figure 16. Negative Battery Cable Frame Grommets.
0307
0307-19


Privacy Statement