DIFFERENTIAL REPLACEMENT - Continued
Figure 51. Top of Transmission.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  901    902    903    904    905  906  907    908    909    910    911  
img
.
TM 5-3805-296-23-4
0276
INSTALLATION-CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
76. Apply sealing compound on threads of differential lock air hose (Figure 50, Item 11).
77. Install differential lock air hose (Figure 50, Item 11) on machine and tighten tube nuts
(Figure 50, Items 10 and 12).
Figure 50. Right Side of Transmission.