Figure 1. Bracket.
Figure 3. Hose and Flange Clamp.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  784    785    786    787    788  789  790    791    792    793    794  
img
.
TM 5-3805-296-23-4
0272
REMOVAL CONTINUED
CAUTION
Plug and cap hoses and fittings to prevent contamination.
NOTE
Tag and mark hoses to aid in installation.
Note routing of hoses to aid in installation.
6. Remove sensor (Figure 2, Item 1) and O-ring (Figure 2, Item 2) from line (Figure 2, Item 3). Discard O-ring.
7. Remove plug (Figure 2, Item 4) from line (Figure 2, Item 3).
8. Remove four bolts (Figure 2, Item 8), washers (Figure 1, Item 7), two flange halves (Figure 2, Item 6), hose
(Figure 2, Item 9), and O-ring (Figure 2, Item 5) from line (Figure 2, Item 3). Discard O-ring.
9. Remove hose (Figure 2, Item 9) from machine.
Figure 2. Sensor and Plug.
0272
0272-4