Figure 2. Negative Battery Cable and Alternator.
Figure 5. A/C Compressor and Cover.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  294    295    296    297    298  299  300    301    302    303    304  
img
.
TM 5-3805-296-23-4
0246
ALTERNATOR BELT REMOVAL CONTINUED
4. Remove tiedown strap (Figure 3, Item 1) from boot (Figure 3, Item 2).
5. Remove boot (Figure 3, Item 2) from negative battery cable eyelets (Figure 3, Item 3).
Figure 3. Negative Battery Cable Boot.
0246
NOTE
Note position and routing of cables.
6. Remove nut (Figure 4, Item 2), lockwasher (Figure 4, Item 1), and negative battery cable (Figure 4, Item 3)
from terminal (Figure 4, Item 4). Discard lockwasher.
Figure 4. Negative Battery Cables and Terminal.
0246