Table 1. Left Rear Turn/Stop Light Does Not Operate Continued.
Table 1. Left Rear Turn/Stop Light Does Not Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  1066    1067    1068    1069    1070  1071  1072    1073    1074    1075    1076  
img
TM 5-3805-296-23-2
0146
Table 1. Left Rear Turn/Stop Light Does Not Operate Continued.
0146
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Using digital multimeter
Left Rear Turn/Stop Light
Continuity Replace hitch wiring
(WP 0540), test for continuity
Does Not Operate
harness (WP 0401).
between connector E-C3
Continued
Proceed to Test Step 17.
terminal 26 (WP 0012, Figure 142)
No Continuity Proceed to step 5.
and all other terminals
in connector E-C3
(WP 0012, Figure 142).
5. Using digital multimeter
Continuity Replace hitch wiring
(WP 0540), test for continuity
harness (WP 0401).
between connector E-C3
Proceed to Test Step 17.
terminal 26 (WP 0012, Figure 142)
No Continuity Proceed to Test
and ground.
Step 13.
Test Step 13. Test for Shorted
Chassis Wiring Harness.
1. Disconnect connector J-C8
(WP 0012, Figure 100)
from connector W-C1
(WP 0012, Figure 99).
2. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C6
Proceed to Test Step 17.
terminal 26 (WP 0012, Figure 141)
No Continuity Proceed to step 3.
and all other terminals
in connector J-C6
(WP 0012, Figure 141).
3. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 17.
terminal 58 (WP 0012, Figure 100)
No Continuity Proceed to step 4.
and all other terminals
in connector J-C8
(WP 0012, Figure 100).
4. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 17.
terminal 58 (WP 0012, Figure 100)
No Continuity Proceed to Test
and ground.
Step 14.
Test Step 14. Test for Shorted Main
Cab Wiring Harness.
1. Remove upper plenum from ROPS
(WP 0504).
2. Disconnect connector P-C1
(WP 0012, Figure 253)
connector W-C7
(WP 0012, Figure 252).