Table 1. All Lights, Horn, and Backup Alarm Fail To Operate Continued.
Table 1. All Lights, Horn, and Backup Alarm Fail To Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  975    976    977    978    979  980  981    982    983    984    985  
img
.
TM 5-3805-296-23-2
0141
Table 1. All Lights, Horn, and Backup Alarm Fail To Operate Continued.
0141
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
12. Turn mode switch on military light
All Lights, Horn, and Backup
Headlights Operate Turn mode
switch to SER. DRIVE position
Alarm Fail To Operate
switch on military light switch to OFF
(TM 5-3805-296-10). Wait
Continued
position (TM 5-3805-296-10).
approximately 30 seconds and
Turn battery disconnect switch to OFF
observe LO headlights.
position (TM 5-3805-296-10).
Replace flood enable relay.
Proceed to Test Step 43.
Headlights Do Not Operate Proceed
to Test Step 5.
Figure 1. Relays on Circuit Breaker Panel.