MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 9. Test for Shorted Turn
All Lights, Horn, and Backup
Signal Switch.
Alarm Fail To Operate
1. Turn mode switch on military light
Continued
switch to OFF position
(TM 5-3805-296-10).
2. Separate boot (Figure 3, Item 1)
from turn signal switch
(Figure 3, Item 2).
3. Disconnect terminal 537
(Figure 3, Item 4) from turn
signal switch terminal 1
(Figure 3, Item 3).