TM 5-3805-296-23-2
0138
Table 1. One or More Park Lights Do Not Operate Continued.
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
One or More Park Lights Do
Continuity Replace hood wiring
Not Operate Continued
(WP 0540), test for continuity
harness (WP 0389).
between connector L-C2
Proceed to Test Step 26.
terminal 6 (WP 0012, Figure 192)
No Continuity Proceed to Test
and ground.
Step 24.
Test Step 24. Test for Shorted
Chassis Wiring Harness.
1. Disconnect connector J-C8
(WP 0012, Figure 100) from
connector W-C1
(WP 0012, Figure 99).
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C6 terminal
Proceed to Test Step 26.
25 (WP 0012, Figure 141) and all
No Continuity Proceed to step 3.
other terminals in connector J-C6
(WP 0012, Figure 141).
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C6
Proceed to Test Step 26.
terminal 25 (WP 0012, Figure 141)
No Continuity Proceed to step 4.
and ground.
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8 terminal
Proceed to Test Step 26.
50 (WP 0012, Figure 100) and all
No Continuity Proceed to step 5.
other terminals in connector J-C8
(WP 0012, Figure 100).
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C1 terminal 6
Proceed to Test Step 26.
(WP 0012, Figure 191) and all
No Continuity Proceed to Test
other terminals in connector J-C1
Step 25.
(WP 0012, Figure 191).
Test Step 25. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector H-C7
(WP 0012, Figure 225) from
connector W-C2
(WP 0012, Figure 224).
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C1 terminal
Proceed to Test Step 26.
50 (WP 0012, Figure 99) and all
No Continuity Proceed to step 3.
other terminals in connector W-C1
(WP 0012, Figure 99).
0138-18