• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 5. Cover and Retaining Hardware on Rear Blackout Lamp Housing.
Table 1. One or More Park Lights Do Not Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  940    941    942    943    944  945  946    947    948    949    950  
img
.
TM 5-3805-296-23-2
0138
Table 1. One or More Park Lights Do Not Operate Continued.
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
One or More Park Lights Do
4. Remove two tiedown straps
Not Operate Continued
(Figure 6, Item 1) from wiring
harness (Figure 6, Item 2) and rear
blackout lamp housing
(Figure 6, Item 3). Discard tiedown
straps.
Figure 6. Tiedown Straps.
0138
5. Disconnect connector AH-C9
(WP 0012, Figure 180) from
connector GND (WP 0012,
Figure 175).
6. Disconnect connector AH-C5
(WP 0012, Figure 176) from
connector 21 (WP 0012,
Figure 175).
7. Turn battery disconnect switch to
ON position (TM 5-3805-296-10).
8. Turn mode switch on military light
switch to SER. DRIVE position
(TM 5-3805-296-10).
9. Using digital multimeter
Voltage 18 to 26 V Replace right rear
(WP 0540), test for voltage
blackout lamp (WP 0352).
between connector AH-C5
Proceed to Test Step 26.
(WP 0012, Figure 176) and
Voltage Less Than 18 V Proceed to
connector AH-C9
Test Step 16.
(WP 0012, Figure 180).
0138-13


Privacy Statement