Figure 2. Instrument Panel Cover and Retaining Hardware.
Table 1. No Power From 12 Volt Power Converter or 12 Volt Auxiliary Port Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  916    917    918    919    920  921  922    923    924    925    926  
img
.
TM 5-3805-296-23-2
0137
Table 1. No Power From 12 Volt Power Converter or 12 Volt Auxiliary Port Continued.
0137
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Remove two bolts (Figure 3,
No Power From 12 Volt
Item 1) and left vent (Figure 3,
Power Converter or 12 Volt
Item 2) from instrument panel
Auxiliary Port Continued
(Figure 3, Item 3).
6. Remove two bolts
(Figure 3, Item 6) and right vent
(Figure 3, Item 7) from instrument
panel (Figure 3, Item 3).
7. Remove six bolts (Figure 3, Item 4)
from instrument panel
(Figure 3, Item 3) and ROPS
(Figure 3, Item 5). Position
instrument panel to access
connector P-C18
(WP 0012, Figure 269).
Figure 3. Instrument Panel and Retaining Hardware.
0137
0137-5