Figure 13. Cover and Retaining Hardware on Rear Blackout Lamp Housing.
NO POWER FROM 12 VOLT POWER CONVERTER OR 12 VOLT AUXILIARY PORT

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  911    912    913    914    915  916  917    918    919    920    921  
img
.
TM 5-3805-296-23-2
0136
Table 1. One or Both Blackout Tail Lights Do Not Operate Continued.
0136
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. If removed, install splash shield
One or Both Blackout Tail
(Figure 14, Item 4), four bushings
Lights Do Not Operate
(Figure 14, Item 3), washers
Continued
(Figure 14, Item 2), and bolts
(Figure 14, Item 1) on machine.
Figure 14. Splash Shield and Retaining Hardware.
0136
7. If lowered, install left frame access
plate (WP 0376).
8. Turn battery disconnect switch to
ON position (TM 5-3805-296-10).
9. Turn mode switch on military light
switch to B.O. MARKER position
(TM 5-3805-296-10).
10. Observe BO tail lights.
Both BO Tail Lights Operate
Troubleshooting complete.
One or Both BO Tail Light Do Not
Operate Repeat troubleshooting from
the beginning.
END OF WORK PACKAGE
0136-22