Figure 25. Front Plate.
DEFROST FAN FAILS TO OPERATE

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  882    883    884    885    886  887  888    889    890    891    892  
img
TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Blower Motor Does Not
7. Turn fan speed switch to position I,
Blower Operates In All Speeds
Operate in One or More
II, III, and IIII (TM 5-3805-296-10)
proceed to Test Step 8.
Speeds Continued
and test output of blower.
Blower Does Not Operate in One or
More Speeds Repeat
troubleshooting from the beginning.
8. Turn fan speed switch to
position O (TM 5-3805-296-10).
9. Start engine (TM 5-3805-296-10).
10. Set heat AC switch to A/C position
(TM 5-3805-296-10).
11. Turn fan speed switch to position I,
Blower Operates In All Speeds
II, III, and IIII (TM 5-3805-296-10)
Troubleshooting complete.
and test output of blower.
Blower Does Not Operate in One or
More Speeds Repeat
troubleshooting from the beginning.
END OF WORK PACKAGE