Figure 20. Insulation.
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  877    878    879    880    881  882  883    884    885    886    887  
img
.
TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 36. Test Headliner Wiring
Blower Motor Does Not
Harness for High Resistance or
Operate in One or More
Open.
Speeds Continued
1. Turn fan speed switch to
position O (TM 5-3805-296-10).
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
3. Remove four bolts (Figure 21,
Item 2) and plate (Figure 21,
Item 1) from headliner (Figure 21,
Item 3).
Figure 21. Plate and Retaining Hardware.
0134
4. Disconnect connector H-C3
(WP 0012, Figure 250) from fan
speed switch (WP 0012,
Figure 249).
5. Connect jumper wire between
terminal 4 and terminal 6 of
connector H-C3 (WP 0012,
Figure 250).
6. Disconnect connector W-C2
(WP 0012, Figure 224) from
connector H-C7 (WP 0012,
Figure 225).
7. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 37.
between connector H-C7
Resistance Greater Than 5.0 Ohms
terminal 12 and terminal 14
Replace headliner wiring harness
(WP 0012, Figure 225).
(WP 0497).
Proceed to Test Step 38.
0134-38