Table 1. 0821 Display Power Supply Diagnostic Codes Continued.
Figure 4. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  497    498    499    500    501  502  503    504    505    506    507  
img
.
TM 5-3805-296-23-2
0100
Table 1. 0821 Display Power Supply Diagnostic Codes Continued.
0100
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Check For Shorted
0821-04 Display Power
Speedometer/Tachometer Display
Supply Voltage Below
Module.
Normal Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove six bolts
(Figure 3, Item 1), washers
(Figure 3, Item 2), and instrument
panel cover (Figure 3, Item 3) from
ROPS (Figure 3, Item 4).
Figure 3. Instrument Panel Cover and Retaining Hardware.
0100
3. Remove two bolts
(Figure 4, Item 1) and left vent
(Figure 4, Item 2) from instrument
panel (Figure 4, Item 3).
4. Remove two bolts
(Figure 4, Item 6) and right vent
(Figure 4, Item 7) from instrument
panel (Figure 4, Item 3).
NOTE
DO NOT disconnect connector P-C1 (WP 0012, Figure 253) from W-C7
(WP 0012, Figure 252).
5. Remove six bolts (Figure 4, Item 4)
from instrument panel
(Figure 4, Item 3) and ROPS
(Figure 4, Item 5). Position
instrument panel to access
connector P-C19
(WP 0012, Figure 270).
0100-8