TM 5-3805-296-23-2
0097
Table 1. 0271 Action Alarm Diagnostic Codes.
0097
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
0271-03 Action Alarm
Voltage Above Normal
Always inspect harness connectors that are involved in the circuit. Poor
connections can often be the cause of a problem in an electrical circuit.
Verify that all connections in the circuit are clean and secure and that all
connections are in good condition. If a problem with the connection is
found, correct the problem and verify that this malfunction or diagnostic
code is active before performing this procedure.
Perform open or short-circuit test at each harness connection to identify
the correct harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Monitoring System Detects Above Normal Voltage on Action Alarm Circuit 410.
POSSIBLE CAUSE
Fuse Panel Wiring Harness Shorted.
Main Cab Wiring Harness Shorted.
Dash Wiring Harness Shorted.
Tractor Operator Monitor.
Test Step 1. Test for Shorted Fuse
Panel Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect connector CG-C6
(WP 0012, Figure 309) from action
alarm connector (WP 0012,
Figure 308).
3. Disconnect connector CG-C1
(WP 0012, Figure 283) from
connector W-C8
(WP 0012, Figure 282).
Continuity Replace fuse panel wiring
harness (WP 0515).
between connector CG-C1
Proceed to Test Step 4.
terminal 12 (WP 0012, Figure 283)
No Continuity Proceed to Test
and all other terminals in
Step 2.
connector CG-C1
(WP 0012, Figure 283).