Table 1. 0263 Sensor Power Supply Diagnostic Codes - Continued.
Table 1. 0263 Sensor Power Supply Diagnostic Codes - Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  441    442    443    444    445  446  447    448    449    450    451  
img
.
TM 5-3805-296-23-2
0096
Table 1. 0263 Sensor Power Supply Diagnostic Codes - Continued.
0096
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
2. Remove two bolts
0263-03 Digital Sensor
(Figure 2, Item 1) and left vent
Power Supply (8V or 12V)
(Figure 2, Item 2) from instrument
Voltage Above Normal
panel (Figure 2, Item 3).
Continued
3. Remove two bolts
(Figure 2, Item 6) and right vent
(Figure 2, Item 7) from instrument
panel (Figure 2, Item 3).
4. Remove six bolts (Figure 2, Item 4)
from instrument panel
(Figure 2, Item 3) and ROPS
(Figure 2, Item 5). Position
instrument panel to access
connector P-C18 (WP 0012,
Figure 269).
Figure 2. Instrument Panel and Retaining Hardware.
0096
5. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor.
6. Using digital multimeter
Continuity Replace dash wiring
(WP 0540), test for continuity
harness (WP 0510).
between connector P-C1 terminal
Proceed to Test Step 4.
9 (WP 0012, Figure 253) and all
No Continuity Proceed to step 7.
other terminals in connector P-C1
(WP 0012, Figure 253).