Table 1. 1282 Apron Control Position Sensor Diagnostic Codes Continued.
EJECTOR CONTROL POSITION SENSOR DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  211    212    213    214    215  216  217    218    219    220    221  
img
TM 5-3805-296-23-2
0077
Table 1. 1282 Apron Control Position Sensor Diagnostic Codes Continued.
077
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
1282-13 Apron Lever
Position Sensor Out of
Perform this test only if condition is active.
Calibration
DIAGNOSTIC CODE SET CONDITION
Transmission/Chassis ECM Detects Joystick Duty Cycle Values Out of Range.
POSSIBLE CAUSE
Implement Control Joystick Requires Calibration.
Test Step 1. Perform Joystick Apron
Lever Sensor Calibration.
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick apron lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Calibration Value Too Low Replace
implement control joystick (WP 0503).
Calibration Value Too Large
Replace implement control joystick
(WP 0503).
END OF WORK PACKAGE
0077-16