Table 1. 1281 Bowl Control Position Sensor Diagnostic Codes Continued.
APRON CONTROL POSITION SENSOR DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  195    196    197    198    199  200  201    202    203    204    205  
img
TM 5-3805-296-23-2
0076
Table 1. 1281 Bowl Control Position Sensor Diagnostic Codes Continued.
076
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
1281-13 Bowl Lever Position
Sensor Out of Calibration
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Transmission/Chassis ECM Detects Joystick Duty Cycle Values Out of Range.
POSSIBLE CAUSE
Implement Control Joystick Requires Calibration.
Test Step 1. Perform Joystick Bowl
Lever Sensor Calibration.
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick bowl lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Calibration Value Too Low Replace
implement control joystick (WP 0503).
Calibration Value Too Large
Replace implement control joystick
(WP 0503).
END OF WORK PACKAGE
0076-16