TM 5-3805-296-23-2
0075
Table 1. 1280 Ejector Reverse Proportional Solenoid Diagnostic Codes Continued.
075
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove four bolts
1280-05 Ejector Reverse
(Figure 5, Item 2), washers
Solenoid Current Below
(Figure 5, Item 1), and cover
Normal Continued
(Figure 5, Item 3) from machine.
Figure 5. Cover.
0075
4. Disconnect connector F-C5
(WP 0012, Figure 156) from
ejector reverse solenoid connector
(WP 0012, Figure 155).
5. Connect jumper wire between
terminal 1 and terminal 2
of connector F-C5
(WP 0012, Figure 156).
6. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
7. At MSD, check for active
1280-6 Ejector Reverse Solenoid
diagnostic code 1280-5 Ejector
Current Above Normal Becomes
Active Replace ejector reverse
Normal (WP 0008).
Proceed to Test Step 6.
1280-5 Ejector Reverse Solenoid
Current Below Normal Remains
Active Proceed to Test Step 2.