TM 5-3805-296-23-2
0075
Table 1. 1280 Ejector Reverse Proportional Solenoid Diagnostic Codes Continued.
075
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 5. Verify Malfunction is
1280-03 Ejector Reverse
Resolved.
1. Ensure all harness connectors are
Normal Continued
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1280-3 Ejector Reverse Solenoid
diagnostic codes (WP 0008).
Voltage Above Normal Becomes
Inactive Proceed to step 4.
1280-3 Ejector Reverse Solenoid
Voltage Above Normal Remains
Active Repeat troubleshooting from
the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install splash shield
(Figure 3, Item 4), four bushings
(Figure 3, Item 3), washers
(Figure 3, Item 2), and bolts
(Figure 3, Item 1) on machine.
6. If lowered, install left frame access
plate (WP 0376).
7. Install cover (Figure 2, Item 3), four
washers (Figure 2, Item 1), and
bolts (Figure 2, Item 2) on
machine.
8. Install hydraulic tube clamp
(Figure 1, Item 4), two washers
(Figure 1, Item 2), and bolts
(Figure 1, Item 3) on mounting
boss (Figure 1, Item 1) and
hydraulic tube (Figure 1, Item 5).
9. Troubleshooting complete.
0075-7