Figure 1. Hydraulic Tube Clamp.
Figure 3. Splash Shield and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  159    160    161    162    163  164  165    166    167    168    169  
img
.
TM 5-3805-296-23-2
0075
Table 1. 1280 Ejector Reverse Proportional Solenoid Diagnostic Codes Continued.
075
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove four bolts
1280-03 Ejector Reverse
(Figure 2, Item 2), washers
Solenoid Voltage Above
(Figure 2, Item 1), and cover
Normal Continued
(Figure 2, Item 3) from machine.
Figure 2. Cover.
0075
4. Disconnect connector F-C5
(WP 0012, Figure 156) from
ejector reverse solenoid connector
(WP 0012, Figure 155).
5. Disconnect connector F-C8
(WP 0012, Figure 146)
from connector AE-C5
(WP 0012, Figure 145).
6. Using digital multimeter
Continuity Replace implement wiring
(WP 0540), test for continuity
harness (WP 0349).
between connector F-C8
Proceed to Test Step 5.
terminal 4 (WP 0012, Figure 146)
No Continuity Proceed to Test
and all other terminals
Step 2.
in connector F-C8
(WP 0012, Figure 146).
Test Step 2. Test for Shorted Draft
Frame and Bowl Side Wiring
Harness.
1. Disconnect connector AE-C1
(WP 0012, Figure 144)
from connector E-C2
(WP 0012, Figure 143).
0075-4


Privacy Statement
Press Release
Contact