Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.
074
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 5. Perform Ejector
1279-13 Ejector Forward
Solenoid Calibration.
Solenoid Out of Calibration
Continued
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform ejector solenoid calibration
Calibration Successful
(WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
Calibrating (never completes
process) Proceed to Test Step 6.
Calibration Value Too Low Replace
Calibration Value Too Large
Replace ejector forward solenoid
(WP 0438).
Test Step 6. Perform Joystick Ejector
Lever Sensor Calibration.
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick ejector lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
Calibration Value Too Low Replace
implement control joystick (WP 0503).
Calibrate joystick (WP 0173).
Calibration Value Too Large
Replace implement control joystick
(WP 0503).
Calibrate joystick (WP 0173).
END OF WORK PACKAGE