Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.
Figure 7. Implement Pump Pressure Status.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  152    153    154    155    156  157  158    159    160    161    162  
img
TM 5-3805-296-23-2
0074
Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.
074
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Verify Malfunction is
1279-06 Ejector Forward
Resolved.
Solenoid Current Above
Normal Continued
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1279-6 Ejector Forward Solenoid
diagnostic codes (WP 0008).
Current Above Normal Becomes
Inactive Proceed to step 4.
1279-6 Ejector Forward Solenoid
Current Above Normal Remains
Active Repeat troubleshooting from
the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install splash shield
(Figure 6, Item 4), four bushings
(Figure 6, Item 3), washers
(Figure 6, Item 2), and bolts
(Figure 6, Item 1) on machine.
6. If lowered, install left frame access
plate (WP 0376).
7. Install front cover
(Figure 5, Item 3), four washers
(Figure 5, Item 1), and bolts
(Figure 5, Item 2) on machine.
8. Troubleshooting complete.