TM 5-3805-296-23-2
0074
Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.
074
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Verify Malfunction is
1279-06 Ejector Forward
Resolved.
Normal Continued
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1279-6 Ejector Forward Solenoid
diagnostic codes (WP 0008).
Current Above Normal Becomes
Inactive Proceed to step 4.
1279-6 Ejector Forward Solenoid
Current Above Normal Remains
Active Repeat troubleshooting from
the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install splash shield
(Figure 6, Item 4), four bushings
(Figure 6, Item 3), washers
(Figure 6, Item 2), and bolts
(Figure 6, Item 1) on machine.
6. If lowered, install left frame access
plate (WP 0376).
7. Install front cover
(Figure 5, Item 3), four washers
(Figure 5, Item 1), and bolts
(Figure 5, Item 2) on machine.
8. Troubleshooting complete.
0074-17