Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.
Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  148    149    150    151    152  153  154    155    156    157    158  
img
.
TM 5-3805-296-23-2
0074
Table 1. 1279 Ejector Forward Proportional Solenoid Diagnostic Codes Continued.
074
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Ejector
1279-06 Ejector Forward
Forward Solenoid.
Solenoid Current Above
1. Turn ignition switch and battery
Normal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove four bolts
(Figure 5, Item 2), washers
(Figure 5, Item 1), and front cover
(Figure 5, Item 3) from machine.
Figure 5. Front Cover.
0074
3. Disconnect connector F-C6
(WP 0012, Figure 158) from
ejector forward solenoid connector
(WP 0012, Figure 157).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
0074-13