Table 1. 0700 Transmission Gear Position Sensor Diagnostic Codes Continued.
Table 1. 0700 Transmission Gear Position Sensor Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  955    956    957    958    959  960  961    962    963    964    965  
img
. . . . . . . . . . . . . . . . .
TM 5-3805-296-23-1
0064
Table 1. 0700 Transmission Gear Position Sensor Diagnostic Codes Continued.
064
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
4. Using digital multimeter
0700-02 Transmission Gear
Continuity at Any Test Point
(WP 0540), test for continuity
Sensor Erratic, Intermittent,
Replace transmission wiring harness
between the following:
or Incorrect Continued
(WP 0266).
a. Connector A-C1 terminal 30
Proceed to Test Step 20.
(WP 0012, Figure 106) and
No Continuity at Any Test Point
ground.
Proceed to Test Step 9.
b. Connector A-C1 terminal 29
(WP 0012, Figure 106) and
ground.
c.
Connector A-C1 terminal 28
(WP 0012, Figure 106) and
ground.
d. Connector A-C1 terminal 27
(WP 0012, Figure 106) and
ground.
e. Connector A-C1 terminal 26
(WP 0012, Figure 106) and
ground.
Test Step 9. Test for Shorted Chassis
Wiring Harness.
1. Disconnect connector J-C8
(WP 0012, Figure 100)
from connector W-C1
(WP 0012, Figure 99).
2. Using digital multimeter
Continuity at Any Test Point
(WP 0540), test for continuity
Replace chassis wiring harness
between the following:
(WP 0305).
a. Connector J-C3 terminal 30
Proceed to Test Step 20.
(WP 0012, Figure 101) and all
No Continuity at Any Test Point
other terminals in connector
Proceed to step 3.
J-C3 (WP 0012, Figure 101).
b. Connector J-C3 terminal 29
(WP 0012, Figure 101) and all
other terminals in connector
J-C3 (WP 0012, Figure 101).
c.
Connector J-C3 terminal 28
(WP 0012, Figure 101) and all
other terminals in connector
J-C3 (WP 0012, Figure 101).
d. Connector J-C3 terminal 27
(WP 0012, Figure 101) and all
other terminals in connector
J-C3 (WP 0012, Figure 101).
e. Connector J-C3 terminal 26
(WP 0012, Figure 101) and all
other terminals in connector
J-C3 (WP 0012, Figure 101).