Figure 26. Instrument Panel Cover and Retaining Hardware.
Table 1. 0590 Communication Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  895    896    897    898    899  900  901    902    903    904    905  
img
. . . .
TM 5-3805-296-23-1
0061
Table 1. 0590 Communication Diagnostic Codes Continued.
061
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
6. Remove two bolts
0590-12 Wrong Response
(Figure 27, Item 1) and left vent
From Engine Control
(Figure 27, Item 2) from instrument
Module Continued
panel (Figure 27, Item 3).
7. Remove two bolts
(Figure 27, Item 6) and right vent
(Figure 27, Item 7) from instrument
panel (Figure 27, Item 3).
8. Remove six bolts
(Figure 27, Item 4) from instrument
panel (Figure 27, Item 3) and
ROPS (Figure 27, Item 5). Position
instrument panel to access
connector P-C18
(WP 0012, Figure 269).
Figure 27. Instrument Panel and Retaining Hardware.
0061
9. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor.
10. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 16.
between connector W-C16
Resistance Greater Than 5.0 Ohms
terminal 1 and terminal 2
Replace main cab wiring harness
(WP 0012, Figure 87).
(WP 0505).
Proceed to Test Step 20.
0061-47