Figure 4. Instrument Panel Cover and Retaining Hardware.
Table 1. 0590 Communication Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  859    860    861    862    863  864  865    866    867    868    869  
img
. . . .
TM 5-3805-296-23-1
0061
Table 1. 0590 Communication Diagnostic Codes Continued.
061
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
6. Remove two bolts
0590-02 Engine Control
(Figure 5, Item 1) and left vent
Module Incorrect Signal
(Figure 5, Item 2) from instrument
Continued
panel (Figure 5, Item 3).
7. Remove two bolts
(Figure 5, Item 6) and right vent
(Figure 5, Item 7) from instrument
panel (Figure 5, Item 3).
8. Remove six bolts (Figure 5, Item 4)
from instrument panel
(Figure 5, Item 3) and ROPS
(Figure 5, Item 5). Position
instrument panel to
access connector P-C18
(WP 0012, Figure 269).
Figure 5. Instrument Panel and Retaining Hardware.
0061
9. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor.
10. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 11.
between connector W-C16
Resistance Greater Than 5.0 Ohms
terminal 1 and terminal 2
Replace main cab wiring harness
(WP 0012, Figure 87).
(WP 0505).
Proceed to Test Step 12.
0061-11