Table 1. 0590 Communication Diagnostic Codes Continued.
061
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 12. Verify Malfunction is
0590-02 Engine Control
Resolved.
Module Incorrect Signal
1. Ensure all harness connectors are
Continued
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
590-2 Engine Control Module
diagnostic codes (WP 0008).
Incorrect Signal Becomes Inactive
Proceed to step 4.
590-2 Engine Control Module
Incorrect Signal Remains Active
Repeat troubleshooting from the
beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install instrument panel
(Figure 9, Item 3) with six bolts
(Figure 9, Item 4) on ROPS
(Figure 9, Item 5).
6. If removed, install right vent
(Figure 9, Item 7) with two bolts
(Figure 9, Item 6) on instrument
panel (Figure 9, Item 3).
7. If removed, install left vent
(Figure 9, Item 2) with two bolts
(Figure 9, Item 1) on instrument
panel (Figure 9, Item 3).
0061-14