• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 0041 Eight-Volt Sensor Supply Diagnostic Codes Continued.
Table 1. 0041 Eight-Volt Sensor Supply Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  753    754    755    756    757  758  759    760    761    762    763  
img
. . . . . . . .
TM 5-3805-296-23-1
0053
Table 1. 0041 Eight-Volt Sensor Supply Diagnostic Codes Continued.
053
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Using digital multimeter
0041-03 8 Volt DC Supply
Continuity Replace main cab wiring
(WP 0540), test for continuity
Voltage Above Normal
harness (WP 0505).
between connector W-C1
Continued
Proceed to Test Step 5.
terminal 16 (WP 0012, Figure 99)
No Continuity Proceed to step 4.
and all other terminals
in connector W-C1
(WP 0012, Figure 99).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 5.
terminal 11 (WP 0012, Figure 88)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C12
(WP 0012, Figure 88).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C12
Proceed to Test Step 5.
terminal 11 (WP 0012, Figure 88)
No Continuity Replace transmission/
and all terminals in connector W-
chassis ECM (WP 0495).
C13 (WP 0012, Figure 89).
Proceed to Test Step 5.
Test Step 5. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
41-3 8 Volt DC Supply Voltage Above
diagnostic codes (WP 0008).
Normal Becomes Inactive
Troubleshooting complete.
41-3 8 Volt DC Supply Above Normal
Remains Active Repeat
troubleshooting from the beginning.
NOTE
0041-04 8 Volt DC Supply
Voltage Below Normal
Always inspect harness connectors that are involved in the circuit. Poor
connections can often be the cause of a problem in an electrical circuit.
Verify that all connections in the circuit are clean and secure and that all
connections are in good condition. If a problem with the connection is
found, correct the problem and verify that this malfunction or diagnostic
code is active before performing this procedure.
Perform open or short-circuit test at each harness connection to identify
the correct harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
0053-4


Privacy Statement
Press Release