Table 1. E539 High Intake Manifold Air Temperature Event Code Continued.
EIGHT-VOLT SENSOR SUPPLY DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  749    750    751    752    753  754  755    756    757    758    759  
img
. . .
TM 5-3805-296-23-1
0052
Table 1. E539 High Intake Manifold Air Temperature Event Code Continued.
052
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Verify Malfunction is
E539 High Intake Manifold
Resolved.
Air Temperature - Warning
1. Turn battery disconnect switch to
or Derate Continued
ON position and start engine
(TM 5-3805-296-10).
2. At MSD, check for active
Diagnostic Code(s) Active
diagnostic code(s) (WP 0008).
Diagnose and repair active diagnostic
code(s) (WP 0005).
Proceed to step 3.
No Active Diagnostic Code(s)
Proceed to step 3.
3. Verify correct operation of machine
(TM 5-3805-296-10).
4. At MSD, check for active event
E539 High Intake Manifold Air
code(s) (WP 0008).
Temperature Becomes Inactive
Troubleshooting complete.
E539 High Intake Manifold Air
Temperature Remains Active
Repeat troubleshooting from the
beginning.
END OF WORK PACKAGE