Figure 2. Throttle Lock Switch Status.
Table 1. 0549 Throttle Lock Diagnostic Code Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  645    646    647    648    649  650  651    652    653    654    655  
img
. . . . . . . . . . . .
TM 5-3805-296-23-1
0036
Table 1. 0549 Throttle Lock Diagnostic Code Continued.
036
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Using digital multimeter
0549-02 Throttle Lock
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
Enable Switch Erratic,
harness (WP 0515).
between connector CG-C1
Intermittent, or Incorrect
Proceed to Test Step 19.
terminal 65 (WP 0012, Figure 283)
Continued
No Continuity Proceed to step 4.
and all other terminals
in connector CG-C1
(WP 0012, Figure 283).
4. Using digital multimeter
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
harness (WP 0515).
between connector CG-C1
Proceed to Test Step 19.
terminal 65 (WP 0012, Figure 283)
No Continuity Proceed to Test
and ground.
Step 5.
Test Step 5. Test Fuse Panel Wiring
Harness for High Resistance or
Open.
1. Connect jumper wire between
terminal 1 and terminal 3
of connector CG-C7
(WP 0012, Figure 307).
2. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 6.
between connector CG-C1
Resistance Greater Than 5.0 Ohms
terminal 63 and terminal 65
Replace fuse panel wiring harness
(WP 0012, Figure 283).
(WP 0515).
Proceed to Test Step 19.
Test Step 6. Test for Shorted Main
Cab Wiring Harness.
1. Remove jumper wire from
terminal 1 and terminal 3
of connector CG-C7
(WP 0012, Figure 307).
2. Disconnect connector W-C16
(WP 0012, Figure 87)
from connector CL-C3
(WP 0012, Figure 86).
3. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C8 terminal
Proceed to Test Step 19.
65 (WP 0012, Figure 282) and all
No Continuity Proceed to step 4.
other terminals in connector W-C8
(WP 0012, Figure 282).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C16
Proceed to Test Step 19.
terminal 5 (WP 0012, Figure 87)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C16
(WP 0012, Figure 87).
0036-6