TM 5-3805-296-23-1
0008
DISCONNECTING MSD CONTINUED
If 24V DC Cable Connection was Used
0008
1. Disconnect NATO power cable (Figure 29, Item 3) from machine NATO slave receptacle (TM 5-3805-296-10).
Install protective cap (Figure 29, Item 2) on NATO power cable.
2. Disconnect NATO power cable (Figure 29, Item 3) from DC input power connector (Figure 29, Item 4) by
turning metal ring on NATO power cable counterclockwise. Install protective cap (Figure 29, Item 5) on DC
input power connector (Figure 29, Item 4).
3. Install NATO power cable (Figure 29, Item 3) in MSD case (Figure 4, Item 1).
If 115 V AC Input Cord Connection was Used
0008
1. Disconnect AC input cord (Figure 29, Item 6) from 115V AC voltage source.
2. Disconnect AC input cord (Figure 29, Item 6) from AC input connector (Figure 29, Item 7).
3. Install AC input cord (Figure 29, Item 6) in MSD case (Figure 29, Item 1).
If 230V AC Connection was Used
0008
1. Disconnect 230V AC plug adapter (Figure 29, Item 8) from 230V AC voltage supply.
2. Remove 230V AC plug adapter (Figure 29, Item 8) from AC input cord (Figure 29, Item 6).
3. Install 230V AC plug adapter (Figure 29, Item 8) in MSD case (Figure 29, Item 1).
4. Disconnect AC input cord (Figure 29, Item 6) from AC input connector (Figure 29, Item 7).
5. Install AC input cord (Figure 29, Item 6) in MSD case (Figure 29, Item 1).
Figure 29. MSD Power Converter/Battery Charger and Power Cables.
0008