Table 1. Operator Troubleshooting - Continued.
Figure 1. Brake Actuator.

Operators Manual For Military 621G Scraper Page Navigation
  97    98    99    100    101  102  103    104    105    106    107  
img
. . . . . . . . . . . . .
TM 5-3805-296-10
0010
Table 1. Operator Troubleshooting - Continued.
0010
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
14. Front or Rear Washer
1. Check window washer fluid reser-
Window Washer Fluid Reservoir
Does Not Operate Prop-
voir (WP 0012).
Has Adequate Fluid -
erly
Proceed to step 2.
Window Washer Fluid Reservoir Is
Empty -
Fill window washer fluid reservoir (WP
0012).
Window Washer Operates.
Troubleshooting complete.
Circuit Breaker Is Not Tripped -
2. Check for tripped window wipers
and washers circuit breaker (circuit
Notify Field Maintenance.
breaker 35) at fuse panel (WP
0018).
Circuit Breaker Is Tripped -
Reset circuit breaker (WP 0018).
Proceed to step 3.
3. Operate front and rear washers
Washers Operate -
(WP 0004).
Troubleshooting complete. If circuit
breaker trips again, notify Field
Maintenance.
Front or Rear Window Washer Does
Not Operate -
Notify Field Maintenance.
15. Front or Rear Wiper
1. Check for tripped window wipers
Circuit Breaker Is Not Tripped -
Does Not Operate Prop-
and washers circuit breaker (circuit
Notify Field Maintenance.
erly
breaker 35) at fuse panel (WP
0018).
Circuit Breaker Is Tripped -
Reset circuit breaker (WP 0018).
Proceed to step 2.
2. Operate front and rear wipers (WP
Front and Rear Wipers Operate -
0004).
Troubleshooting complete. If circuit
breaker trips again, notify Field
Maintenance.
Front or Rear Wiper Does Not
Operate -
Notify Field Maintenance.