COMPARTMENT CONTROL MODULE.
POWER DISTRIBUTION UNIT PANEL. - Continued

Technical Manual For Collective Protection Equipment, Guardrail With Accessories
Page Navigation
  121    122    123    124    125  126  127    128    129    130    131  
img
. . . . .
TM
3-4240-309-20&P
2-18. POWER DISTRIBUTION UNIT PANEL.
This task covers:
a. Replacement of glow lamp (p. 2-117).
b. Replacement of electrical connector covers (J3, J5 and J6) (p. 2-118)
c. Replacement of electrical connector cover (J7) (p. 2-118)
Materials/Parts
Tools
Rags (item 6, app D)
General Mechanics Tool Kit
Dry cleaning solvent (item 3, app D)
SC 5180-90-CL-N26
ACTION
ITEM
LOCATION
Power
1. Loosen screws (l).
Glow lamp
Distribution
2. Open access cover (2) on power distribution
Unit Panel
unit panel (3).
3. Unscrew indicator light lens (4).
WARNING
To prevent electrical hazard to personnel,
ensure power source is disconnected before
continuing procedure.
4. Remove glow lamp (5) from indicator light
socket (6).
1. Insert glow lamp (5) in indicator light lens (4).
2. Screw indicator light lens (4) into light socket
(6).
3. Close access cover (2) against power
distribution unit panel (3) and secure with
screws (1).
2-117