2-15. M87 GAS-PARTICULATE FILTER UNIT (CONT).
ACTION
ITEM
LOCATION
1.
Slip new dust exhaust blower (7) into bracket
Dust exhaust blower
Gas-Particulate
assembly (15), and install screw (17).
Filter Unit
NOTE
Be sure dust collector outlet (16) points
toward bracket assembly mounting foot before
tightening screw (17).
2.
Slip exhaust sleeve (6) and hose clamps (4
and 5) onto dust exhaust blower (7) inlet. Do
not tighten hose clamps.
3.
Slip exhaust sleeve (10), hose clamps (8 and 9),
and exhaust muffler (11) onto dust collector
outlet (16). Tighten hose clamps.
4.
Slip exaust sleeve (6) and dust exaust blower
(7) onto dust collector outlet (16).
5.
Install and tighten screws (12), washers (13),
and nuts (14) through bracket assembly (15)
foot and front filter unit stand (18). Tighten
hose clamps (4 and 5) on dust exaust blower
(7) inlet.
6.
Connect plug P6 (2) to power distribution unit
(3).
7.
Set POWER switch (1) on compartment control
module to ON.