ACTION
ITEM
LOCATION
1.
Set POWER switch (1) on compartment control
Dust exhaust blower
Gas-Particulate
module to OFF.
Filter Unit
Disconnect plug P6 (2) at power distribution
2.
unit (3).
Loosen two hose clamps (4 and 5) on exhaust
3.
sleeve (6) at dust exhaust blower (7) inlet.
Loosen two hose clamps (8 and 9) on exhaust
4.
sleeve (10) at exhaust muffler (11). Remove
exhaust muffler (11), exhaust sleeve (10), and
two hose clamps (8 and 9) from dust exhaust
blower (7).
Remove two screws (12), washers (13), and
5.
nuts (14) from bracket assembly (15). Pull dust
exhaust blower (1) free from dust collector
outlet (16).
Remove exaust sleeve (6) and hose clamps (4
6.
and 5) from dust collector outlet (16).
Remove screw (17) from bracket assembly (15),
7.
and slip dust exhaust blower (7) out of bracket
assembly (15).
Retain screw (17) and bracket assembly (15) for
8.
installation of new dust exhaust blower.