WARNING
TM 9-6230-210-13&P
(10) Filling fuel tank.
REMOVE
INSTALL
LEGEND
1 CAP
2 TANK
(a) Remove fuel tank cap (1) by turning 1/4 turn counter-clockwise.
When handling gasoline, always provide a metal-to-metal contact between the con-
tainer and the fuel tank. This will prevent a spark from being generated, as gasoline
flows over the metallic surfaces.
(b) Fill tank (2) with gasoline.
(c) Place cap on tank and turn 1/4 turn clockwise to lock.
(11) Tower power cable.
(a) Refer to schematic wiring diagram and install power cable to control panel and generator set.
NOTE
The Floodlight Set operates from the 120-volt single-phase terminals on the engine-
generator set.
(b) For operation with a 3kW generator set, the floodligt set is connected to terminals L1 and L2 of the
generator output terminal board or generator panel (GP). The black wire and green wire in the main
power cable (cable from the control panel to the generator panel) shall be solderd together and
connected to terminal L2, and the white wire is connected to terminal L1.
4-14