TM 9-6230-210-13&P
LEGEND
5 COLLAR
6 TOWER CABLE
7 CONNECTOR
8 COLLAR
9 BALLAST BOX CABLE
10 CONNECTOR
11 COLLAR
12 GENERATOR POWER
C A B L E
13 CONNECTOR
e. Unscrew collar (5) and withdraw tower power cable (6) from connector (7).
f. Unscrew collar (8) and withdraw ballast box cable (9) from connector (10).
g. Unscrew collar (11) and withdraw generator power cable (12) from connector (13).
LEGEND
14 NUT
15 WAHSER
16 SCREW
17 CONTROL PAN-
EL
18 SPACER
NOTE
Ground lug will come loose when top nut is removed.
h. Remove three nuts (14), washers (15), and screws (16).
i. Remove control panel (17).
j. Remove three spacers (18).
5-5