TM 9-4940-568-34
5-18
5-3. GENERATOR SET REPLACEMENT (CONT).
(18)
Push electrical wires with electrical tube
(29) and electrical connector (30) through
generator circuit panel (16) and nut (28)
and tighten nut.
NOTE
Install hoses and connectors as
noted during removal.
(19)
Push two wires (27) out through generator
circuit panel (16) and install on heater fuel
pump (14).
(20)
Install neutral wire (25) on insulator (26).
(21)
Install ground wire (23) on block (24).
(22)
Install three wires (21) on circuit breaker
(22).
(23)
Install wires (19) on wire connection strip
(20).
14
16
20
27
19
16
23
25
28
22
29
21
30
26
24