TM 9-4940-568-34
5-15
b.
Installation.
59
8
55
53
52
54
60
57
58
56
8
Generator set enclosure weighs approximately 2450 lbs (1111 kg). Attach suitable
lifting device to prevent possible injury to personnel.
(1)
With the aid of assistants, position S-hooks (60) and attach lifting device to generator set enclosure (8).
(2)
With the aid of assistants, position generator set enclosure (8) on flatrack (59).
(3)
Remove lifting device and four S-hooks (60) from generator set enclosure (8).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from
open fire and use in well-ventilated area. If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately with soap and water.
(4)
Apply sealing compound to four screws (56).
(5)
With the aid of assistants, install generator set enclosure (8) on flatrack (59) using four washers (58),
washers (57) and screws (56). Tighten four screws (56) to 210 ft-lb (285 N.m).
(6)
Install four large rubber covers (55) and four small rubber covers (54) on generator set enclosure (8).
(7)
Install two brackets (53) with self-tapping screws (52) on generator set enclosure (8).