TM 9-4940-568-20
9-30
9-4. ARGON REGULATOR REPLACEMENT (CONT).
18
22
17
21
13
6
6
14
15
16
20
20
19
19
(10)
Remove pressure gage (13) from argon regulator (6).
(11)
Open drawer E1 and remove four locknuts (14) , washers (15), screws (16) and bracket (17) from cabinet
(18). Discard locknuts.
(12)
Remove four locknuts (19), washers (20), screws (21), plate (22) and argon regulator (6) from bracket
(17). Discard locknuts.