TM 9-4940-568-20
9-31
b. Installation.
18
22
17
21
13
6
6
14
15
16
20
20
19
19
NOTE
Install hoses, fittings, elbows, and adapters as noted prior to removal.
(1)
Install argon regulator (6) on bracket (17) with plate (22), four screws (21), washers (20) and locknuts
(19).
(2)
Open drawer E1 and install bracket (17) on cabinet (18) with four screws (16), washers (15) and locknuts
(14).
Adhesives, solvents and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin
or clothing, wash immediately with soap and water.
Only apply sealing compound on threads specified in Steps. Failure to comply may result
in injury or death to personnel and damage to equipment.
(3)
Apply sealing compound to threads of pressure gage (13).
(4)
Install pressure gage (13) on argon regulator (6).