TM 9-4940-568-20
8-83
b. Installation.
Radiator assembly weighs 51 lbs
(23 kg). Attach suitable lifting
device prior to
removal/installation to prevent
possible injury to personnel.
(1)
Attach lifting device to radiator (9).
Adhesives, solvents and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in
wellventilated area. If adhesive,
solvent or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(2)
Apply sealing compound to threads of drain
valve (21) and hose adapter (22).
(3)
Install hose adapter (22) and drain valve
(21) on radiator (9).
(4)
Install hose (20) and hose clamp (19) on
drain valve (21).
Ensure radiator is fully supported
by lifting device prior to
installation of screws in Step (5)
and (6). Failure to comply may
result in severe injury to
personnel.
(5)
With aid of an assistant, install radiator (9)
with three screws (18) on right side of
radiator (9).
(6)
Install three screws (17) on left side of
radiator (9).
(7)
Install right side radiator panel (16) with
four screws (15).
21
22
19
20
17
15
16
18
9