TM 9-4940-568-20
8-26
8-8. ETHER START AID ASSEMBLY REPLACEMENT (CONT).
b. Installation.
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
NOTE
Install cable ties as necessary.
(1)
Apply sealing compound to threads of
atomizer (16).
NOTE
Atomizer opening at end of
fitting must point straight up
when installed in cylinder head.
(2)
Install atomizer (16), ether tube (11) and nut
(15) on engine cylinder head (17).
(3)
Install solenoid valve (4) on generator panel
(9) using two screws (13) and nuts (14).
(4)
Connect two wires (12) and crimp to
solenoid valve (4).
(5)
Install fitting (10) and ether tube (11) to
solenoid valve (4).
13
15
16
17
11
10
4
11
12
14
9