1
3
2
4
5
TM 9-4940-568-20
8-18
8-6. ENGINE OIL FILTER HEAD AND GASKET REPLACEMENT (CONT).
b. Disassembly.
(1)
Clean area around plug (1).
(2)
Remove plug (1), preformed packing (2),
spring (3) and plunger (4) from oil filter
head (5). Discard preformed packing.
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so
may result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all sealing surfaces.
(2)
Clean all parts with drycleaning solvent.
Compressed air used for cleaning
purposes will not exceed 30 psi
(207 kPa). Use only with
effective chip guarding and
personal protective equipment
(goggles/shield, gloves, etc. ) or
injury to personnel may result.
(3)
Dry all parts with compressed air.
(4)
Check plunger, spring and bore for cracks.
Polished areas on plunger and bore are
acceptable.
(5)
Verify plunger moves freely in bore.